<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://aowis.org/index.php?action=history&amp;feed=atom&amp;title=Reference%3A10_m_concrete_water_tower_5%2C000l</id>
	<title>Reference:10 m concrete water tower 5,000l - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://aowis.org/index.php?action=history&amp;feed=atom&amp;title=Reference%3A10_m_concrete_water_tower_5%2C000l"/>
	<link rel="alternate" type="text/html" href="https://aowis.org/index.php?title=Reference:10_m_concrete_water_tower_5,000l&amp;action=history"/>
	<updated>2026-06-08T09:41:42Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.45.3</generator>
	<entry>
		<id>https://aowis.org/index.php?title=Reference:10_m_concrete_water_tower_5,000l&amp;diff=417&amp;oldid=prev</id>
		<title>Samuel at 05:01, 27 April 2026</title>
		<link rel="alternate" type="text/html" href="https://aowis.org/index.php?title=Reference:10_m_concrete_water_tower_5,000l&amp;diff=417&amp;oldid=prev"/>
		<updated>2026-04-27T05:01:47Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 05:01, 27 April 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l2&quot;&gt;Line 2:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;AOWIS Reference Implementation: 10 m Concrete Water Tower with 5,000 L nylon tank. Designed for &amp;#039;&amp;#039;&amp;#039;locally-buildable construction&amp;#039;&amp;#039;&amp;#039; using available materials.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;AOWIS Reference Implementation: 10 m Concrete Water Tower with 5,000 L nylon tank. Designed for &amp;#039;&amp;#039;&amp;#039;locally-buildable construction&amp;#039;&amp;#039;&amp;#039; using available materials.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;This blueprint is &#039;&#039;&#039;non-normative&#039;&#039;&#039; and intended as a &#039;&#039;&#039;practical, low-tech reference&#039;&#039;&#039; for local water infrastructure.&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;gallery&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;gallery&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key mediawiki:diff:1.41:old-192:rev-417:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Samuel</name></author>
	</entry>
	<entry>
		<id>https://aowis.org/index.php?title=Reference:10_m_concrete_water_tower_5,000l&amp;diff=192&amp;oldid=prev</id>
		<title>Samuel: Created page with &quot;{{DISPLAYTITLE:10 m Concrete Water Tower 5,000 L}}  AOWIS Reference Implementation: 10 m Concrete Water Tower with 5,000 L nylon tank. Designed for &#039;&#039;&#039;locally-buildable construction&#039;&#039;&#039; using available materials.  This blueprint is &#039;&#039;&#039;non-normative&#039;&#039;&#039; and intended as a &#039;&#039;&#039;practical, low-tech reference&#039;&#039;&#039; for local water infrastructure.  &lt;gallery&gt; File:Water tower concrete 5000l 02.jpg File:Water tower concrete 5000l 01.jpg &lt;/gallery&gt;  == Functional Purpose ==  * Store 5,0...&quot;</title>
		<link rel="alternate" type="text/html" href="https://aowis.org/index.php?title=Reference:10_m_concrete_water_tower_5,000l&amp;diff=192&amp;oldid=prev"/>
		<updated>2026-04-02T03:16:17Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{{DISPLAYTITLE:10 m Concrete Water Tower 5,000 L}}  AOWIS Reference Implementation: 10 m Concrete Water Tower with 5,000 L nylon tank. Designed for &amp;#039;&amp;#039;&amp;#039;locally-buildable construction&amp;#039;&amp;#039;&amp;#039; using available materials.  This blueprint is &amp;#039;&amp;#039;&amp;#039;non-normative&amp;#039;&amp;#039;&amp;#039; and intended as a &amp;#039;&amp;#039;&amp;#039;practical, low-tech reference&amp;#039;&amp;#039;&amp;#039; for local water infrastructure.  &amp;lt;gallery&amp;gt; File:Water tower concrete 5000l 02.jpg File:Water tower concrete 5000l 01.jpg &amp;lt;/gallery&amp;gt;  == Functional Purpose ==  * Store 5,0...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{DISPLAYTITLE:10 m Concrete Water Tower 5,000 L}}&lt;br /&gt;
&lt;br /&gt;
AOWIS Reference Implementation: 10 m Concrete Water Tower with 5,000 L nylon tank. Designed for &amp;#039;&amp;#039;&amp;#039;locally-buildable construction&amp;#039;&amp;#039;&amp;#039; using available materials.&lt;br /&gt;
&lt;br /&gt;
This blueprint is &amp;#039;&amp;#039;&amp;#039;non-normative&amp;#039;&amp;#039;&amp;#039; and intended as a &amp;#039;&amp;#039;&amp;#039;practical, low-tech reference&amp;#039;&amp;#039;&amp;#039; for local water infrastructure.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
File:Water tower concrete 5000l 02.jpg&lt;br /&gt;
File:Water tower concrete 5000l 01.jpg&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Functional Purpose ==&lt;br /&gt;
&lt;br /&gt;
* Store 5,000 L of water in a tank elevated ~10 m for gravity-fed irrigation&lt;br /&gt;
* Provide a higher-head water supply for greater pressure&lt;br /&gt;
* Integrate optionally with AOWIS Field Controllers for water level monitoring&lt;br /&gt;
&lt;br /&gt;
== Structural Concept ==&lt;br /&gt;
&lt;br /&gt;
* 10 m high simple reinforced concrete frame tower&lt;br /&gt;
* Supports a standard 5,000 L nylon tank (locally available)&lt;br /&gt;
* Open-top tank for inspection and filling&lt;br /&gt;
* Integrated Ladder for maintenance&lt;br /&gt;
* Tank is secured to the tower by being fully enclosed by a brick or concrete wall&lt;br /&gt;
* Designed to be assembled with available tools and local labor&lt;br /&gt;
&lt;br /&gt;
== Hydraulic Layout ==&lt;br /&gt;
&lt;br /&gt;
* Tank outlet supplies water to outlets, homes, irrigation zones by gravity&lt;br /&gt;
* Isolation valve allows manual control&lt;br /&gt;
* Optional integration with a small pump for secondary supply zones&lt;br /&gt;
&lt;br /&gt;
== Safety Considerations ==&lt;br /&gt;
&lt;br /&gt;
* Ladder and hatch should be used carefully&lt;br /&gt;
* Ladder should be protected from being accessed by children&lt;br /&gt;
* Ensure the foundation is anchored down to the bedrock&lt;br /&gt;
* Ensure good quality concrete and enough reinforcing steel of acceptable quality&lt;br /&gt;
* Basic manual valve operations keeps it operational during brownouts&lt;br /&gt;
&lt;br /&gt;
== Manual Operation Pathways ==&lt;br /&gt;
&lt;br /&gt;
* Tank filling and emptying can be done manually if electronics fail&lt;br /&gt;
* Simple paper-based logs or measurements supported&lt;br /&gt;
&lt;br /&gt;
== Controller Integration Points ==&lt;br /&gt;
&lt;br /&gt;
* Optional water level sensor for Field Controller logging&lt;br /&gt;
** AOWIS control can read tank level for irrigation scheduling&lt;br /&gt;
* Manual bypass always available - water supply continues even if electronics are offline&lt;br /&gt;
&lt;br /&gt;
== Versioning Note ==&lt;/div&gt;</summary>