Jump to content

Measurement:Unit Identifiers

From AOWIS
Revision as of 12:21, 28 July 2026 by Samuel (talk | contribs)

AOWIS uses the canonical SI-based engineering units specified in Units. UCUM[1] is the normative syntax and code system for their machine-readable unit identifiers.

AOWIS defines a canonical set of UCUM unit identifiers used across all system interfaces, storage formats, APIs, and inter-system data exchanges.

Unit identifiers are machine-readable tokens and are not intended to represent typographic or human-readable unit notation.

General Rules

  • All unit identifiers MUST conform to UCUM.
  • Each measurement quantity MUST be assigned exactly one UCUM unit identifier as its canonical unit identifier.
  • Canonical unit identifiers MUST be used consistently across all AOWIS-compliant systems, interfaces, storage formats, APIs, and inter-system data exchanges.
  • Canonical unit identifiers MUST be interpreted independently of locale, display format, implementation, and system context.
  • Canonical unit identifiers MUST remain stable across AOWIS-compliant systems and data formats.

Requirements

REQ-MEAS-UNI-001: All unit identifiers MUST conform to UCUM.

REQ-MEAS-UNI-002: Each measurement quantity MUST be assigned exactly one UCUM unit identifier as its canonical unit identifier.

REQ-MEAS-UNI-003: The canonical unit identifier assigned to a measurement quantity MUST be used consistently across all AOWIS-compliant systems, interfaces, storage formats, APIs, and inter-system data exchanges.

REQ-MEAS-UNI-004: The measurement quantity identifier defines what is measured, while the unit identifier defines the unit in which it is expressed.

Canonical Measurement Quantities and Units

Length and Spatial Quantities

Quantity / Name Definition Canonical Unit (SI symbol) Serialized Unit EPANET Mapping
length Linear spatial extent m m Pipe/link length (SI-normalized EPANET model)
elevation Vertical height relative to datum m m Node elevation (SI-normalized EPANET model)
distance Spatial separation between points m m Derived geometric quantity
position_offset Relative spatial offset magnitude m m Not explicitly represented in EPANET

Area and Volume

Quantity / Name Definition Canonical Unit (SI symbol) Serialized Unit EPANET Mapping
area Two-dimensional spatial extent m2 Not directly used
volume Storage volume m3 Tank volume (SI-normalized EPANET model)

Flow and Transport

Quantity / Name Definition Canonical Unit (SI symbol) Serialized Unit EPANET Mapping
volumetric_flow_rate Volume per unit time m³/s m3_per_s Link flow (SI-normalized EPANET model)
mass_flow_rate Mass per unit time kg/s kg_per_s Not directly represented (derived)

Pressure and Stress

Quantity / Name Definition Canonical Unit (SI symbol) Serialized Unit EPANET Mapping
pressure Force per unit area in fluid system Pa pa Node pressure (SI-normalized EPANET model)
stress Internal material stress Pa pa Not represented

Time

Quantity / Name Definition Canonical Unit (SI symbol) Serialized Unit EPANET Mapping
time Simulation or observation time s s Simulation time (EPANET internal time normalized to seconds)
duration Time interval length s s Simulation duration / reporting intervals

Electrical Quantities

Quantity / Name Definition Canonical Unit (SI symbol) Serialized Unit
current Rate of electric charge flow A a
voltage Electric potential difference V v
resistance Opposition to electric current flow Ω ohm
power Rate of energy transfer W w
energy Work or transferred electrical energy J j
capacitance Ability to store electric charge F f

Data Representation Format

Data Model

Concrete AOWIS data structures and field definitions are specified by the AOWIS Server Model.

Measurement fields defined by the model MUST use the canonical units specified on this page.