AOWIS | This page is the normative registry of canonical measurement quantities and units used by AOWIS. | ||
The representation and conversion rules governing these quantities are defined in [[Measurement:Units]]. | |||
UCUM<ref name="UCUM">Unified Code for Units of Measure (UCUM) https://ucum.org</ref> is used for machine-readable physical unit identifiers. | |||
== Identifier and Field-Naming Rules == | |||
The canonical unit assigned to each measurement quantity in this registry is authoritative. | |||
When a unit identifier is explicitly represented, it MUST use the canonical UCUM identifier defined here. | |||
The AOWIS identifier suffix is an ASCII-safe naming convention used for fixed-schema field names, property names, database columns, and similar technical identifiers. | |||
The suffix convention is: | |||
* division is represented by <code>_per_</code>; | |||
* multiplication is represented by <code>_</code>; | |||
* unit symbols are normalized to lower case where required for identifier naming; | |||
* quantity-specific semantic qualifiers MAY be included where a literal unit-only suffix would be ambiguous; | |||
* dimensionless fields with canonical UCUM unit <code>1</code> normally omit a unit suffix. | |||
For example: | |||
<pre> | <pre> | ||
m3/h -> m3_per_h | |||
m/s -> m_per_s | |||
kW.h/m3 -> kw_h_per_m3 | |||
mm2/(100.m) -> mm2_per_100m | |||
</pre> | |||
The AOWIS identifier suffix is not itself a UCUM unit identifier. | |||
For generic or dynamically typed measurement values, the resolved measurement quantity determines the canonical unit through this registry. | |||
== Length and Distance Quantities == | |||
{| class="wikitable" | |||
! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | |||
|- | |||
| <code>length</code> || Linear spatial extent along an object or path || metre (m) || <code>m</code> || <code>m</code> || Pipe and link length | |||
|- | |||
| <code>elevation</code> || Vertical height relative to an engineering or hydraulic datum || metre (m) || <code>m</code> || <code>m</code> || Junction, tank, reservoir, and terrain elevation | |||
|- | |||
| <code>altitude</code> || Vertical position reported by a geographic positioning source || metre (m) || <code>m</code> || <code>m</code> || Geographic altitude; not necessarily suitable as hydraulic elevation | |||
|- | |||
| <code>distance</code> || Spatial separation between positions || metre (m) || <code>m</code> || <code>m</code> || Derived geometric distance | |||
|- | |||
| <code>vertical_offset</code> || Vertical difference between referenced elevations or heads || metre (m) || <code>m</code> || <code>m</code> || Elevation, tank-bottom, and reservoir-head offsets | |||
|- | |||
| <code>link_diameter</code> || Internal or nominal diameter of a pipe or valve || millimetre (mm) || <code>mm</code> || <code>mm</code> || EPANET pipe and valve diameter | |||
|- | |||
| <code>tank_diameter</code> || Internal diameter of a cylindrical storage tank || metre (m) || <code>m</code> || <code>m</code> || EPANET tank diameter | |||
|- | |||
| <code>darcy_weisbach_roughness_height</code> || Absolute pipe-wall roughness height used by the Darcy-Weisbach formulation || millimetre (mm) || <code>mm</code> || <code>mm</code> || EPANET Darcy-Weisbach pipe roughness | |||
|} | |||
== Geographic Coordinate Quantities == | |||
{| class="wikitable" | |||
! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | |||
|- | |||
| <code>latitude</code> || Angular position north or south of the equator || degree (°) || <code>deg</code> || <code>deg</code> || WGS 84 latitude | |||
|- | |||
| <code>longitude</code> || Angular position east or west of the prime meridian || degree (°) || <code>deg</code> || <code>deg</code> || WGS 84 longitude | |||
|- | |||
| <code>projected_easting</code> || Eastward coordinate within a projected coordinate reference system || metre (m) || <code>m</code> || <code>m</code> || Projected-coordinate easting | |||
|- | |||
| <code>projected_northing</code> || Northward coordinate within a projected coordinate reference system || metre (m) || <code>m</code> || <code>m</code> || Projected-coordinate northing | |||
|- | |||
| <code>local_x</code> || X coordinate within an explicitly defined local engineering coordinate system || metre (m) || <code>m</code> || <code>m</code> || Local coordinates when the coordinate system is defined in metres | |||
|- | |||
| <code>local_y</code> || Y coordinate within an explicitly defined local engineering coordinate system || metre (m) || <code>m</code> || <code>m</code> || Local coordinates when the coordinate system is defined in metres | |||
|} | |||
== Area and Volume Quantities == | |||
{| class="wikitable" | |||
! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | |||
|- | |||
| <code>area</code> || Two-dimensional spatial extent || square metre (m²) || <code>m2</code> || <code>m2</code> || Tank cross-sectional area and other geometric areas | |||
|- | |||
| <code>volume</code> || Three-dimensional spatial extent or storage capacity || cubic metre (m³) || <code>m3</code> || <code>m3</code> || Tank volume | |||
|} | |||
== Flow and Transport Quantities == | |||
= | {| class="wikitable" | ||
! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | |||
|- | |||
| <code>volumetric_flow_rate</code> || Volume transported per unit time || cubic metre per hour (m³/h) || <code>m3/h</code> || <code>m3_per_h</code> || Demand, link flow, leakage flow, emitter flow, and pump-curve flow | |||
|- | |||
| <code>velocity</code> || Rate of linear movement || metre per second (m/s) || <code>m/s</code> || <code>m_per_s</code> || Link flow velocity | |||
|} | |||
== | == Hydraulic Head, Pressure, and Stress Quantities == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Quantity | ! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | ||
|- | |- | ||
| | | <code>hydraulic_head</code> || Total mechanical energy per unit weight of fluid expressed as an equivalent fluid-column height || metre (m) || <code>m</code> || <code>m</code> || Junction, reservoir, and tank hydraulic head | ||
|- | |- | ||
| | | <code>pressure_head</code> || Fluid pressure expressed as an equivalent fluid-column height || metre (m) || <code>m</code> || <code>m</code> || EPANET node pressure, pressure-driven demand thresholds, and pressure-control valve settings | ||
|- | |- | ||
| | | <code>water_level</code> || Height of a water surface relative to a defined local reference level || metre (m) || <code>m</code> || <code>m</code> || Initial, minimum, maximum, and simulated tank levels | ||
|- | |- | ||
| | | <code>head_gain</code> || Increase in hydraulic head across an energy-adding component || metre (m) || <code>m</code> || <code>m</code> || Pump curves and pump simulation results | ||
|- | |||
| <code>head_loss</code> || Reduction in hydraulic head across a hydraulic component || metre (m) || <code>m</code> || <code>m</code> || Pipes, valves, and other energy-dissipating components | |||
|- | |||
| <code>head_loss_gradient</code> || Hydraulic head loss per unit pipe length || metre per kilometre (m/km) || <code>m/km</code> || <code>m_per_km</code> || EPANET pipe head-loss reporting | |||
|- | |||
| <code>pressure</code> || Normal force per unit area within a fluid system || kilopascal (kPa) || <code>kPa</code> || <code>kpa</code> || Physical pressure measurements, sensors, SCADA data, and external exchange | |||
|- | |||
| <code>stress</code> || Internal force per unit area within a material || megapascal (MPa) || <code>MPa</code> || <code>mpa</code> || Structural and material analysis | |||
|} | |} | ||
=== | == Time Quantities == | ||
{| class="wikitable" | |||
! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | |||
|- | |||
| <code>elapsed_time</code> || Time elapsed from a defined simulation or process origin || second (s) || <code>s</code> || <code>s</code> || Simulation elapsed time and time-based control triggers | |||
|- | |||
| <code>duration</code> || Length of a time interval || second (s) || <code>s</code> || <code>s</code> || Simulation duration and time steps | |||
|- | |||
| <code>time_of_day</code> || Time elapsed since the start of the current day || second (s) || <code>s</code> || <code>s</code> || Simulation start time and clock-time controls | |||
|} | |||
== Hydraulic Coefficients and Other Dimensionless Quantities == | |||
The canonical UCUM unit identifier for all quantities in this section is <code>1</code>. The AOWIS unit suffix is omitted. | |||
Semantic terms such as <code>ratio</code>, <code>factor</code>, <code>coefficient</code>, <code>multiplier</code>, and <code>exponent</code> describe the quantity and are not unit suffixes. | |||
{| class="wikitable" | {| class="wikitable" | ||
! Quantity | ! Measurement Quantity Identifier !! Definition !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | ||
|- | |||
| <code>hazen_williams_roughness_coefficient</code> || Hazen-Williams pipe roughness coefficient || <code>1</code> || none || EPANET Hazen-Williams roughness | |||
|- | |||
| <code>chezy_manning_roughness_coefficient</code> || Chezy-Manning pipe roughness coefficient || <code>1</code> || none || EPANET Chezy-Manning roughness | |||
|- | |||
| <code>minor_loss_coefficient</code> || Coefficient representing local hydraulic losses || <code>1</code> || none || Pipe and valve minor loss; TCV setting | |||
|- | |||
| <code>darcy_weisbach_friction_factor</code> || Darcy-Weisbach friction factor || <code>1</code> || none || Pipe simulation result | |||
|- | |||
| <code>pump_speed_ratio</code> || Pump rotational speed relative to nominal or reference speed || <code>1</code> || none || Pump setting, result, pattern, control, and rule values | |||
|- | |||
| <code>pattern_multiplier</code> || Factor applied by a hydraulic or energy pattern || <code>1</code> || none || EPANET pattern factor | |||
|- | |||
| <code>demand_multiplier</code> || Global factor applied to base demands || <code>1</code> || none || EPANET demand multiplier | |||
|- | |||
| <code>pressure_exponent</code> || Exponent used by the pressure-driven demand relation || <code>1</code> || none || EPANET pressure exponent | |||
|- | |||
| <code>emitter_exponent</code> || Exponent used by the emitter pressure-flow relation || <code>1</code> || none || EPANET emitter exponent | |||
|- | |- | ||
| | | <code>reaction_order</code> || Order of a bulk, wall, or tank reaction equation || <code>1</code> || none || EPANET reaction order | ||
|- | |- | ||
| volume || | | <code>specific_gravity</code> || Fluid density relative to a defined reference density || <code>1</code> || none || EPANET specific gravity | ||
|- | |||
| <code>relative_viscosity</code> || Kinematic viscosity relative to the solver reference || <code>1</code> || none || EPANET relative viscosity | |||
|- | |||
| <code>relative_diffusivity</code> || Molecular diffusivity relative to the solver reference || <code>1</code> || none || EPANET relative diffusivity | |||
|- | |||
| <code>mixing_fraction</code> || Fraction of tank volume assigned to the applicable mixing zone || <code>1</code> || none || EPANET tank mixing fraction | |||
|- | |||
| <code>hydraulic_accuracy</code> || Relative hydraulic convergence criterion || <code>1</code> || none || EPANET hydraulic accuracy | |||
|- | |||
| <code>hydraulic_damping_limit</code> || Relative threshold controlling solver damping or status checks || <code>1</code> || none || EPANET damping limit | |||
|- | |||
| <code>relative_error</code> || Relative numerical error || <code>1</code> || none || Hydraulic simulation statistics | |||
|- | |||
| <code>flow_balance_ratio</code> || Ratio of total outflow to total inflow || <code>1</code> || none || EPANET flow-balance reporting | |||
|- | |||
| <code>quality_mass_balance_ratio</code> || Water-quality mass-conservation ratio || <code>1</code> || none || EPANET quality mass-balance reporting | |||
|} | |} | ||
== | == Percentage Quantities == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Quantity | ! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | ||
|- | |||
| <code>efficiency</code> || Ratio of useful output to total input expressed as a percentage || percent (%) || <code>%</code> || <code>percent</code> || Pump efficiency and efficiency curves | |||
|- | |||
| <code>relative_flow</code> || Flow relative to a defined reference flow || percent (%) || <code>%</code> || <code>percent</code> || Valve characteristic curves | |||
|- | |||
| <code>valve_position</code> || Valve opening position relative to its operating range || percent (%) || <code>%</code> || <code>percent</code> || Position-control valves | |||
|- | |||
| <code>source_trace_percentage</code> || Proportion of water originating from a specified source node || percent (%) || <code>%</code> || <code>percent</code> || EPANET source-trace analysis | |||
|- | |||
| <code>operating_time_percentage</code> || Fraction of a reporting period during which equipment operates || percent (%) || <code>%</code> || <code>percent</code> || Pump energy reporting | |||
|- | |- | ||
| | | <code>demand_reduction_percentage</code> || Reduction in delivered demand relative to requested demand || percent (%) || <code>%</code> || <code>percent</code> || Hydraulic statistics | ||
|- | |- | ||
| | | <code>leakage_loss_percentage</code> || Leakage loss relative to total system inflow || percent (%) || <code>%</code> || <code>percent</code> || Leakage statistics | ||
|} | |} | ||
== | == Reaction and Leakage Quantities == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Quantity | ! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | ||
|- | |||
| <code>first_order_bulk_reaction_coefficient</code> || First-order reaction-rate coefficient within the bulk fluid || per day (d⁻¹) || <code>/d</code> || <code>per_d</code> || Global, pipe, and tank first-order bulk reactions | |||
|- | |- | ||
| | | <code>first_order_wall_reaction_coefficient</code> || First-order reaction-rate coefficient at a pipe wall || metre per day (m/d) || <code>m/d</code> || <code>m_per_d</code> || Global and pipe first-order wall reactions | ||
|- | |- | ||
| | | <code>leak_area_per_100m_pipe_length</code> || Effective leak area assigned per 100 metres of pipe length || square millimetre per 100 metres (mm²/100 m) || <code>mm2/(100.m)</code> || <code>mm2_per_100m</code> || EPANET 2.3 FAVAD leak area; EPANET uses 100 project length units and the adapter converts when required<ref name="EPANET23">OWA-EPANET 2.3 release notes https://github.com/OpenWaterAnalytics/EPANET/blob/v2.3/ReleaseNotes2_3.md</ref> | ||
|- | |||
| <code>leak_area_expansion_per_pressure_head</code> || Increase in effective leak area per unit pressure head || square millimetre per metre of pressure head (mm²/m) || <code>mm2/m</code> || <code>mm2_per_m_head</code> || EPANET 2.3 FAVAD leak expansion | |||
|} | |} | ||
== | == Water Quality Quantities == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Quantity | ! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | ||
|- | |||
| <code>chemical_concentration</code> || Mass concentration of a chemical substance in water || milligram per litre (mg/L) || <code>mg/L</code> || <code>mg_per_l</code> || Chemical quality input and results | |||
|- | |- | ||
| | | <code>chemical_mass_flow_rate</code> || Chemical mass introduced into or transported through the system per unit time || milligram per minute (mg/min) || <code>mg/min</code> || <code>mg_per_min</code> || EPANET mass-booster source strength and source mass rate | ||
|- | |- | ||
| | | <code>water_age</code> || Time elapsed since water entered the modelled distribution system || hour (h) || <code>h</code> || <code>h</code> || EPANET water-age analysis | ||
|} | |} | ||
== | == Power, Energy, and Electrical Quantities == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Quantity | ! Measurement Quantity Identifier !! Definition !! Canonical Unit !! UCUM Identifier !! AOWIS Identifier Suffix !! AOWIS Model / EPANET Mapping | ||
|- | |||
| <code>power</code> || Rate of energy transfer || kilowatt (kW) || <code>kW</code> || <code>kw</code> || Pump power and electrical power | |||
|- | |- | ||
| | | <code>energy</code> || Work performed or energy transferred || kilowatt-hour (kWh) || <code>kW.h</code> || <code>kw_h</code> || Pump energy consumption | ||
|- | |- | ||
| | | <code>energy_intensity</code> || Energy consumed per unit volume || kilowatt-hour per cubic metre (kWh/m³) || <code>kW.h/m3</code> || <code>kw_h_per_m3</code> || Pump energy-use reporting | ||
|- | |- | ||
| | | <code>electric_current</code> || Rate of electric charge flow || ampere (A) || <code>A</code> || <code>a</code> || Electrical model | ||
|- | |- | ||
| | | <code>voltage</code> || Electric potential difference || volt (V) || <code>V</code> || <code>v</code> || Electrical model | ||
|- | |- | ||
| | | <code>electrical_resistance</code> || Opposition to electric current flow || ohm (Ω) || <code>Ohm</code> || <code>ohm</code> || Electrical model | ||
|- | |- | ||
| capacitance || Ability to store electric charge || F | | <code>capacitance</code> || Ability to store electric charge || farad (F) || <code>F</code> || <code>f</code> || Electrical model | ||
|} | |} | ||
== Context-Dependent Quantity Resolution == | |||
Some Model concepts resolve to different registered measurement quantities depending on their context. The representation requirements for such values are defined in [[Measurement:Units]] and, where applicable, the corresponding Measurement subsystem specification. | |||
{ | |||
{| class="wikitable" | |||
! Model Concept !! Resolved Measurement Quantity | |||
|- | |||
| Valve setting || PRV, PSV, and PBV: <code>pressure_head</code>; FCV: <code>volumetric_flow_rate</code>; TCV: <code>minor_loss_coefficient</code>; PCV: <code>valve_position</code>; GPV: curve reference rather than a measurement value | |||
</ | |- | ||
| Pump setting || <code>pump_speed_ratio</code> | |||
|- | |||
| Control trigger || <code>water_level</code>, <code>pressure_head</code>, <code>elapsed_time</code>, or <code>time_of_day</code>, depending on control type | |||
|- | |||
| Control or rule action setting || The measurement quantity supported by the target link type | |||
|- | |||
| Rule premise value || The measurement quantity selected by the rule variable | |||
|- | |||
| Initial or simulated quality || <code>chemical_concentration</code>, <code>water_age</code>, or <code>source_trace_percentage</code>, depending on quality-analysis mode | |||
|- | |||
| Quality-source strength || <code>chemical_concentration</code> or <code>chemical_mass_flow_rate</code>, depending on source type | |||
|- | |||
| Reaction coefficient || The applicable reaction-coefficient quantity determined by reaction order | |||
|- | |||
| Emitter coefficient || Equation-dependent coefficient in <code>Q = C H^n</code>; no single fixed canonical unit applies independently of <code>n</code> | |||
|- | |||
| Generic curve coordinate || The measurement quantity defined by the curve type | |||
|- | |||
| Report threshold || The measurement quantity of the corresponding report field | |||
|- | |||
| EPANET map or backdrop coordinate || The applicable geographic, projected, or local coordinate quantity after the coordinate representation is resolved | |||
|} | |||
== References == | |||
< | <references /> | ||
Latest revision as of 11:12, 19 August 2026
- Part of: Measurement:Main_Page
- Related to: Measurement:Units
This page is the normative registry of canonical measurement quantities and units used by AOWIS.
The representation and conversion rules governing these quantities are defined in Measurement:Units.
UCUM[1] is used for machine-readable physical unit identifiers.
Identifier and Field-Naming Rules
The canonical unit assigned to each measurement quantity in this registry is authoritative.
When a unit identifier is explicitly represented, it MUST use the canonical UCUM identifier defined here.
The AOWIS identifier suffix is an ASCII-safe naming convention used for fixed-schema field names, property names, database columns, and similar technical identifiers.
The suffix convention is:
- division is represented by
_per_; - multiplication is represented by
_; - unit symbols are normalized to lower case where required for identifier naming;
- quantity-specific semantic qualifiers MAY be included where a literal unit-only suffix would be ambiguous;
- dimensionless fields with canonical UCUM unit
1normally omit a unit suffix.
For example:
m3/h -> m3_per_h m/s -> m_per_s kW.h/m3 -> kw_h_per_m3 mm2/(100.m) -> mm2_per_100m
The AOWIS identifier suffix is not itself a UCUM unit identifier.
For generic or dynamically typed measurement values, the resolved measurement quantity determines the canonical unit through this registry.
Length and Distance Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
length |
Linear spatial extent along an object or path | metre (m) | m |
m |
Pipe and link length |
elevation |
Vertical height relative to an engineering or hydraulic datum | metre (m) | m |
m |
Junction, tank, reservoir, and terrain elevation |
altitude |
Vertical position reported by a geographic positioning source | metre (m) | m |
m |
Geographic altitude; not necessarily suitable as hydraulic elevation |
distance |
Spatial separation between positions | metre (m) | m |
m |
Derived geometric distance |
vertical_offset |
Vertical difference between referenced elevations or heads | metre (m) | m |
m |
Elevation, tank-bottom, and reservoir-head offsets |
link_diameter |
Internal or nominal diameter of a pipe or valve | millimetre (mm) | mm |
mm |
EPANET pipe and valve diameter |
tank_diameter |
Internal diameter of a cylindrical storage tank | metre (m) | m |
m |
EPANET tank diameter |
darcy_weisbach_roughness_height |
Absolute pipe-wall roughness height used by the Darcy-Weisbach formulation | millimetre (mm) | mm |
mm |
EPANET Darcy-Weisbach pipe roughness |
Geographic Coordinate Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
latitude |
Angular position north or south of the equator | degree (°) | deg |
deg |
WGS 84 latitude |
longitude |
Angular position east or west of the prime meridian | degree (°) | deg |
deg |
WGS 84 longitude |
projected_easting |
Eastward coordinate within a projected coordinate reference system | metre (m) | m |
m |
Projected-coordinate easting |
projected_northing |
Northward coordinate within a projected coordinate reference system | metre (m) | m |
m |
Projected-coordinate northing |
local_x |
X coordinate within an explicitly defined local engineering coordinate system | metre (m) | m |
m |
Local coordinates when the coordinate system is defined in metres |
local_y |
Y coordinate within an explicitly defined local engineering coordinate system | metre (m) | m |
m |
Local coordinates when the coordinate system is defined in metres |
Area and Volume Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
area |
Two-dimensional spatial extent | square metre (m²) | m2 |
m2 |
Tank cross-sectional area and other geometric areas |
volume |
Three-dimensional spatial extent or storage capacity | cubic metre (m³) | m3 |
m3 |
Tank volume |
Flow and Transport Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
volumetric_flow_rate |
Volume transported per unit time | cubic metre per hour (m³/h) | m3/h |
m3_per_h |
Demand, link flow, leakage flow, emitter flow, and pump-curve flow |
velocity |
Rate of linear movement | metre per second (m/s) | m/s |
m_per_s |
Link flow velocity |
Hydraulic Head, Pressure, and Stress Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
hydraulic_head |
Total mechanical energy per unit weight of fluid expressed as an equivalent fluid-column height | metre (m) | m |
m |
Junction, reservoir, and tank hydraulic head |
pressure_head |
Fluid pressure expressed as an equivalent fluid-column height | metre (m) | m |
m |
EPANET node pressure, pressure-driven demand thresholds, and pressure-control valve settings |
water_level |
Height of a water surface relative to a defined local reference level | metre (m) | m |
m |
Initial, minimum, maximum, and simulated tank levels |
head_gain |
Increase in hydraulic head across an energy-adding component | metre (m) | m |
m |
Pump curves and pump simulation results |
head_loss |
Reduction in hydraulic head across a hydraulic component | metre (m) | m |
m |
Pipes, valves, and other energy-dissipating components |
head_loss_gradient |
Hydraulic head loss per unit pipe length | metre per kilometre (m/km) | m/km |
m_per_km |
EPANET pipe head-loss reporting |
pressure |
Normal force per unit area within a fluid system | kilopascal (kPa) | kPa |
kpa |
Physical pressure measurements, sensors, SCADA data, and external exchange |
stress |
Internal force per unit area within a material | megapascal (MPa) | MPa |
mpa |
Structural and material analysis |
Time Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
elapsed_time |
Time elapsed from a defined simulation or process origin | second (s) | s |
s |
Simulation elapsed time and time-based control triggers |
duration |
Length of a time interval | second (s) | s |
s |
Simulation duration and time steps |
time_of_day |
Time elapsed since the start of the current day | second (s) | s |
s |
Simulation start time and clock-time controls |
Hydraulic Coefficients and Other Dimensionless Quantities
The canonical UCUM unit identifier for all quantities in this section is 1. The AOWIS unit suffix is omitted.
Semantic terms such as ratio, factor, coefficient, multiplier, and exponent describe the quantity and are not unit suffixes.
| Measurement Quantity Identifier | Definition | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|
hazen_williams_roughness_coefficient |
Hazen-Williams pipe roughness coefficient | 1 |
none | EPANET Hazen-Williams roughness |
chezy_manning_roughness_coefficient |
Chezy-Manning pipe roughness coefficient | 1 |
none | EPANET Chezy-Manning roughness |
minor_loss_coefficient |
Coefficient representing local hydraulic losses | 1 |
none | Pipe and valve minor loss; TCV setting |
darcy_weisbach_friction_factor |
Darcy-Weisbach friction factor | 1 |
none | Pipe simulation result |
pump_speed_ratio |
Pump rotational speed relative to nominal or reference speed | 1 |
none | Pump setting, result, pattern, control, and rule values |
pattern_multiplier |
Factor applied by a hydraulic or energy pattern | 1 |
none | EPANET pattern factor |
demand_multiplier |
Global factor applied to base demands | 1 |
none | EPANET demand multiplier |
pressure_exponent |
Exponent used by the pressure-driven demand relation | 1 |
none | EPANET pressure exponent |
emitter_exponent |
Exponent used by the emitter pressure-flow relation | 1 |
none | EPANET emitter exponent |
reaction_order |
Order of a bulk, wall, or tank reaction equation | 1 |
none | EPANET reaction order |
specific_gravity |
Fluid density relative to a defined reference density | 1 |
none | EPANET specific gravity |
relative_viscosity |
Kinematic viscosity relative to the solver reference | 1 |
none | EPANET relative viscosity |
relative_diffusivity |
Molecular diffusivity relative to the solver reference | 1 |
none | EPANET relative diffusivity |
mixing_fraction |
Fraction of tank volume assigned to the applicable mixing zone | 1 |
none | EPANET tank mixing fraction |
hydraulic_accuracy |
Relative hydraulic convergence criterion | 1 |
none | EPANET hydraulic accuracy |
hydraulic_damping_limit |
Relative threshold controlling solver damping or status checks | 1 |
none | EPANET damping limit |
relative_error |
Relative numerical error | 1 |
none | Hydraulic simulation statistics |
flow_balance_ratio |
Ratio of total outflow to total inflow | 1 |
none | EPANET flow-balance reporting |
quality_mass_balance_ratio |
Water-quality mass-conservation ratio | 1 |
none | EPANET quality mass-balance reporting |
Percentage Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
efficiency |
Ratio of useful output to total input expressed as a percentage | percent (%) | % |
percent |
Pump efficiency and efficiency curves |
relative_flow |
Flow relative to a defined reference flow | percent (%) | % |
percent |
Valve characteristic curves |
valve_position |
Valve opening position relative to its operating range | percent (%) | % |
percent |
Position-control valves |
source_trace_percentage |
Proportion of water originating from a specified source node | percent (%) | % |
percent |
EPANET source-trace analysis |
operating_time_percentage |
Fraction of a reporting period during which equipment operates | percent (%) | % |
percent |
Pump energy reporting |
demand_reduction_percentage |
Reduction in delivered demand relative to requested demand | percent (%) | % |
percent |
Hydraulic statistics |
leakage_loss_percentage |
Leakage loss relative to total system inflow | percent (%) | % |
percent |
Leakage statistics |
Reaction and Leakage Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
first_order_bulk_reaction_coefficient |
First-order reaction-rate coefficient within the bulk fluid | per day (d⁻¹) | /d |
per_d |
Global, pipe, and tank first-order bulk reactions |
first_order_wall_reaction_coefficient |
First-order reaction-rate coefficient at a pipe wall | metre per day (m/d) | m/d |
m_per_d |
Global and pipe first-order wall reactions |
leak_area_per_100m_pipe_length |
Effective leak area assigned per 100 metres of pipe length | square millimetre per 100 metres (mm²/100 m) | mm2/(100.m) |
mm2_per_100m |
EPANET 2.3 FAVAD leak area; EPANET uses 100 project length units and the adapter converts when required[2] |
leak_area_expansion_per_pressure_head |
Increase in effective leak area per unit pressure head | square millimetre per metre of pressure head (mm²/m) | mm2/m |
mm2_per_m_head |
EPANET 2.3 FAVAD leak expansion |
Water Quality Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
chemical_concentration |
Mass concentration of a chemical substance in water | milligram per litre (mg/L) | mg/L |
mg_per_l |
Chemical quality input and results |
chemical_mass_flow_rate |
Chemical mass introduced into or transported through the system per unit time | milligram per minute (mg/min) | mg/min |
mg_per_min |
EPANET mass-booster source strength and source mass rate |
water_age |
Time elapsed since water entered the modelled distribution system | hour (h) | h |
h |
EPANET water-age analysis |
Power, Energy, and Electrical Quantities
| Measurement Quantity Identifier | Definition | Canonical Unit | UCUM Identifier | AOWIS Identifier Suffix | AOWIS Model / EPANET Mapping |
|---|---|---|---|---|---|
power |
Rate of energy transfer | kilowatt (kW) | kW |
kw |
Pump power and electrical power |
energy |
Work performed or energy transferred | kilowatt-hour (kWh) | kW.h |
kw_h |
Pump energy consumption |
energy_intensity |
Energy consumed per unit volume | kilowatt-hour per cubic metre (kWh/m³) | kW.h/m3 |
kw_h_per_m3 |
Pump energy-use reporting |
electric_current |
Rate of electric charge flow | ampere (A) | A |
a |
Electrical model |
voltage |
Electric potential difference | volt (V) | V |
v |
Electrical model |
electrical_resistance |
Opposition to electric current flow | ohm (Ω) | Ohm |
ohm |
Electrical model |
capacitance |
Ability to store electric charge | farad (F) | F |
f |
Electrical model |
Context-Dependent Quantity Resolution
Some Model concepts resolve to different registered measurement quantities depending on their context. The representation requirements for such values are defined in Measurement:Units and, where applicable, the corresponding Measurement subsystem specification.
| Model Concept | Resolved Measurement Quantity |
|---|---|
| Valve setting | PRV, PSV, and PBV: pressure_head; FCV: volumetric_flow_rate; TCV: minor_loss_coefficient; PCV: valve_position; GPV: curve reference rather than a measurement value
|
| Pump setting | pump_speed_ratio
|
| Control trigger | water_level, pressure_head, elapsed_time, or time_of_day, depending on control type
|
| Control or rule action setting | The measurement quantity supported by the target link type |
| Rule premise value | The measurement quantity selected by the rule variable |
| Initial or simulated quality | chemical_concentration, water_age, or source_trace_percentage, depending on quality-analysis mode
|
| Quality-source strength | chemical_concentration or chemical_mass_flow_rate, depending on source type
|
| Reaction coefficient | The applicable reaction-coefficient quantity determined by reaction order |
| Emitter coefficient | Equation-dependent coefficient in Q = C H^n; no single fixed canonical unit applies independently of n
|
| Generic curve coordinate | The measurement quantity defined by the curve type |
| Report threshold | The measurement quantity of the corresponding report field |
| EPANET map or backdrop coordinate | The applicable geographic, projected, or local coordinate quantity after the coordinate representation is resolved |
References
- ↑ Unified Code for Units of Measure (UCUM) https://ucum.org
- ↑ OWA-EPANET 2.3 release notes https://github.com/OpenWaterAnalytics/EPANET/blob/v2.3/ReleaseNotes2_3.md